ENERGY SAVING

Coldroom
Door Open Alarm

GBC2000-DOA (Yellow) / GBC2001-DOA (Blue)

Alerts staff if a coldroom door is left open, helping reduce energy consumption in line with Cold Chain Federation energy benchmarking. Two independent door switch inputs, two time ranges, and a relay output on door open or alarm.

DOOR INPUTS

2 Independent

SENSOR TYPE

N/O, N/C or PNP

RELAY OUTPUT

2A @ 250 Vac

DELAY RANGE

0–30 / 0–10 Min

INGRESS

IP65 Rated

SUPPLY

85–264 Vac

ORDER CODE
GBC2000-DOA (Yellow) or GBC2001-DOA (Blue)
HOW IT WORKS

Protecting coldroom temperatures

Two independent door inputs

Monitor up to 2 door switches from a single unit, with door input status LEDs.

Adjustable alarm delay

Choose from 2 customer-configurable time ranges: 0 to 30 minutes or 0 to 10 minutes.

Flexible switch compatibility

Suitable for normally open or normally closed door switches and PNP inductive proximity switches.

Relay output

Relay output on door open or alarm, rated 2A @ 250 Vac / 1A @ 30 Vdc (resistive).

Illuminated sounder

Yellow (GBC2000-DOA) or blue (GBC2001-DOA) illuminated sounder, factory set, with a high/low alarm intensity setting and alarm LEDs.

Supports energy benchmarking

Helps reduce energy consumption in accordance with Cold Chain Federation energy benchmarking, with low power consumption of its own.

SYSTEM OVERVIEW

Unit and compatible door switches

Coldroom Door Open Alarm unit, angled view
GBC2000-DOA / GBC2001-DOA

Door Open Alarm Unit

IP65 Rated
122×120×63 mm
85–264 Vac
Light Grey RAL7035
N/O OR N/C

Door Switch

Compatible Input
12 Vdc / 10 mA
30m Max Cable
Up to 2 Inputs
PNP

Inductive Proximity Switch

Compatible Input
12 Vdc / 10 mA
30m Max Cable
Up to 2 Inputs
TECHNICAL DATA

Full specifications

PARAMETER
VALUE
PHYSICAL
Model
GBC2000-DOA (Yellow) / GBC2001-DOA (Blue)
Dimensions
122 mm W × 120 mm H × 63 mm D
Material
ABS, PC (UV stabilised) — Light Grey RAL7035
Ingress Protection
IP65 to EN 60529
Operating Temperature
0°C to +40°C
SUPPLY
Supply Voltage
85 – 264 Vac / 47 – 63 Hz
AC Current (typical at 230 V)
20 mA
INPUTS
Door Input 1
Normally open or normally closed door switch, or PNP inductive proximity switch
Door Input 2
Normally open or normally closed door switch, or PNP inductive proximity switch
Maximum Cable Length
30 metres
Switched Input Voltage / Current
12 V dc / 10 mA
ALARM
Time Range 1
0 – 30 minutes (customer configurable)
Time Range 2
0 – 10 minutes (customer configurable)
Sounder
Yellow (GBC2000-DOA) or blue (GBC2001-DOA) illuminated sounder, factory set; high/low intensity setting
Indicators
Door input status and alarm LEDs
OUTPUTS
Nominal Switching Capacity
2 A @ 250 Vac / 1 A @ 30 Vdc (resistive)
Relay Function
Switches on door open or alarm
Maximum Switching Power
500 VA / 30 W
Minimum Switching Capacity
100 mA @ 5 Vdc